new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Oct 5

LiteMedCoT-VL: Parameter-Efficient Adaptation for Medical Visual Question Answering

The reasoning gap between large and compact vision-language models (VLMs) limits the deployment of medical AI on portable clinical devices. Compact VLMs of 2--4B parameters can run on resource-constrained hardware but lack the multi-step reasoning capacity needed for interpretable clinical decision support. Existing knowledge distillation methods transfer answers without the reasoning process behind them. Medical visual question answering (VQA) serves as a testbed for this problem, as it requires models to integrate visual evidence with clinical knowledge through structured reasoning chains. We introduce LiteMedCoT-VL, a pipeline that transfers chain-of-thought reasoning from a 235B teacher model to 2B student models through LoRA-based fine-tuning on explanation-enriched training data. All inference is conducted without image captions by default, simulating the clinical scenario in which a physician interprets a medical image directly without an accompanying radiology report. On the PMC-VQA benchmark, LiteMedCoT-VL achieves 64.9% accuracy, exceeding the zero-shot Qwen3-VL-4B baseline of 53.9% by 11.0 percentage points and outperforming all published baselines. This result indicates that a 2B model with reasoning distillation can match or exceed models with twice the parameters. Visual grounding analysis shows that the model relies on image content rather than exploiting textual priors. Our code is publicly available at https://anonymous.4open.science/r/LiteMedCoT-VL.

  • 5 authors
·
May 9

Do Medical Vision Language Models Actually See? A Counterfactual Grounding Framework and Hard-Negative Contrastive Training for Visually-Reliant Medical VLMs

Large vision language models (VLMs) report strong accuracy on medical question-answering, yet it remains unclear whether they reason from visual evidence or exploit textual shortcuts. We introduce a counterfactual evaluation framework that decouples visual and textual contributions by substituting input images with controlled surrogates blank, pixel-shuffled, image-absent, and CLIP-retrieved hard negatives and derive a suite of grounding metrics including the Visual Reliance Score (VRS) and Visual Hallucination Rate (VHR). We further introduce CORAL (COntrastive Retrieval-Augmented Learning), a 7B-parameter LoRA fine-tune of Qwen2.5-VL-7B trained with a Contrastive Grounding Objective (CGO) that penalises answer invariance under hard-negative image swaps. On a paired controlled evaluation across four closed-form medical VQA benchmarks (PathVQA, PMC-VQA, SLAKE, VQA-RAD; n=400 total), CORAL improves macro accuracy by +6.7 pp (P(Delta>0)=0.988) and reduces VHR by 8.0 pp (P<0.001) over the matched Qwen2.5-VL-7B base; neither MedVLThinker RL variant achieves a significant gain on either metric. Cross-domain diagnostics further reveal that image substitution costs only <=6.5 pp on medical benchmarks versus 48-61 pp on general-domain tasks, situating the grounding gap that CGO targets. We discuss evaluation limitations openly including train/eval benchmark overlap and underpowered secondary metrics and release our framework, training code, and model weights to support reproducible grounding audits of medical VLMs.

  • 5 authors
·
Jul 3

Prompt4Trust: A Reinforcement Learning Prompt Augmentation Framework for Clinically-Aligned Confidence Calibration in Multimodal Large Language Models

Multimodal large language models (MLLMs) hold considerable promise for applications in healthcare. However, their deployment in safety-critical settings is hindered by two key limitations: (i) sensitivity to prompt design, and (ii) a tendency to generate incorrect responses with high confidence. As clinicians may rely on a model's stated confidence to gauge the reliability of its predictions, it is especially important that when a model expresses high confidence, it is also highly accurate. We introduce Prompt4Trust, the first reinforcement learning (RL) framework for prompt augmentation targeting confidence calibration in MLLMs. A lightweight LLM is trained to produce context-aware auxiliary prompts that guide a downstream task MLLM to generate responses in which the expressed confidence more accurately reflects predictive accuracy. Unlike conventional calibration techniques, Prompt4Trust specifically prioritizes aspects of calibration most critical for safe and trustworthy clinical decision-making. Beyond improvements driven by this clinically motivated calibration objective, our proposed method also improves task accuracy, achieving state-of-the-art medical visual question answering (VQA) performance on the PMC-VQA benchmark, which is composed of multiple-choice questions spanning diverse medical imaging modalities. Moreover, our framework trained with a small downstream task MLLM showed promising zero-shot generalization to larger MLLMs in our experiments, suggesting the potential for scalable calibration without the associated computational costs. This work demonstrates the potential of automated yet human-aligned prompt engineering for improving the the trustworthiness of MLLMs in safety critical settings. Our codebase can be found at https://github.com/xingbpshen/prompt4trust.

  • 4 authors
·
Jul 12, 2025